FCW 17

Standards

AWS/ASME SFA - 5.20 E71T-12M-J
AWS/ASME SFA - 5.20 E71T-1M-J
AWS/ASME SFA - 5.20 E71T-9M-J
AWS/ASME SFA - 5.36 E71T1-M21A4-CS1
EN ISO 17632 - A T46 4 P M21 1 H5
TS EN ISO 17632 - A T46 4 P M21 1 H5

Properties And Applications

Rutile type flux cored wire, designed for welding applications which required good toughness values down to -40°C service temperatures, in steel construction, piping, machine fabrication, shipbuilding and especially offshore structures. Used with M21 mix shielding gas. Owing to its easily controllable weld pool and fast freezing slag particularly suited for welding in all position. Good gap-bridging property in thick sections, has low spatter loss, finely ripped pore-free welds blending into base metal without undercut. Easy slag removal even in fillet and narrow grooves.  

Materials

EN DIN
S185 - S355J0 St 33- St 52.3
P235TR2 - P355T2 St 37.4 - St 52.4
P235G1TH, P255G1TH St 35.8 - St 45.8
P295GH 17Mn4
P235GH, P265GH H I, H II
S255N - S420N StE 255 - StE 420
L210 - L415NB StE 210.7 - StE 415.7
L290MB - L450MB StE 290.7 TM - StE 445.7 TM
GE 200, GE 240 GS 38, GS 45
AH 32, EH 36
A, B, D, E
X42 - X65

Typical Chemical Values of Weld Metal

Type of AnalysisCSiMnNi
Weld Deposit0.050,501.400.40

Typical Mechanical Values of Weld Metal(%)

Test ConditionProtection GasYield Strength (N/mm²)Tensile Strength (N/mm²)Elongation A5 (%)Charpy V-Notch Properties (J)
As weldedM2152058028-30°C → 100-40°C → 80

* Chemical compositon and mechanical properties are valid when using shielding gas EN ISO 14175 - C1 (%100 CO2) .

Application Information

Welding Positions :
Fcw 17 Kaynak Pozisyonu Fcw 17 Kaynak Pozisyonu Fcw 17 Kaynak Pozisyonu Fcw 17 Kaynak Pozisyonu Fcw 17 Kaynak Pozisyonu Fcw 17 Kaynak Pozisyonu Fcw 17 Kaynak Pozisyonu

Polarity:

Fcw 17 Kutuplama DC(+)

Protection Gas:

M21

Welding Parameters & Efficiency :

Packaging Information

Product CodeDiameter (mm)Weight Of The Box (kg)Number Of Boxes Per PackageWeight Of The PackagePackaging Type
31006EIAM21.2015.0116.0Plastic Spool (D300) VAC

Storage & Re-Drying Information

>Shouldn t be exposed to high statical load and impact.